record Retrofit Kit – Door operator for replacement and modification

Adjustable parameters
record Retrofit Kit
Door movement up to 0.75 m / s (adjustable)
General technical specifications
Width of passage A 800 – 3 000 mm
Height of passage G 3 000 mm
Door leaf weight max. 2 x 200 kg
Power supply voltage 230 VAC
Rated power 140 W
Consumption in standby mode 20 W
Operating conditions
Ambient temperature –15°C to +50°C
Humidity range up to 85% rel. humidity, non-condensing
Functional safety
Standard compliance DIN 18650, EN 16005, TÜV-Certified P 4052/13, P 4053/13